Universal Journal of Electrical and Electronic Engineering Vol. 2(4), pp. 178 - 182
DOI: 10.13189/ujeee.2014.020406
Reprint (PDF) (902Kb)


Measurement of Power Quality on the COTEK S1500-124 Inverter’S Terminals in Case of Linear Load Supplying


Dusan Medved *, Martin Kanalik
Technical University of Kosice, Department of Electric Power Engineering, Masiarska 74, 04201 Kosice, Slovak Republic

ABSTRACT

This paper describes the approach and results of power quality measurement at the outputs of DC/AC inverter COTEK S1500-124 supplying a linear load. There were used load examples as a classic light bulb of 150 W nominal power and an air heater with adjustable power chosen as linear load. The measurement was realized for purposes of verification of power quality indexes at the outputs of DC/AC inverter COTEK S1500-124 declared by its manufacturer.

KEYWORDS
Power Quality, Power Quality Measurement, Harmonics, DC/AC Inverter

Cite This Paper in IEEE or APA Citation Styles
(a). IEEE Format:
[1] Dusan Medved , Martin Kanalik , "Measurement of Power Quality on the COTEK S1500-124 Inverter’S Terminals in Case of Linear Load Supplying," Universal Journal of Electrical and Electronic Engineering, Vol. 2, No. 4, pp. 178 - 182, 2014. DOI: 10.13189/ujeee.2014.020406.

(b). APA Format:
Dusan Medved , Martin Kanalik (2014). Measurement of Power Quality on the COTEK S1500-124 Inverter’S Terminals in Case of Linear Load Supplying. Universal Journal of Electrical and Electronic Engineering, 2(4), 178 - 182. DOI: 10.13189/ujeee.2014.020406.